ELECTRICAL SYSTEM 16-57
Radiator Fan System
Radiator Fan Motor Inspection
•
Disconnect the connector [A] in the fan lead.
•
Using two auxiliary wires, supply battery voltage to the fan
motor.
If the fan does not rotate, the fan motor is defective and
must be replaced.
Radiator Fan Motor Lead Connections:
BL → Battery (+)
BK → Battery (–)
Radiator Fan Breaker Inspection
•
Remove:
Seat (see Seat Removal in the Frame chapter)
Radiator Fan Breaker [A]
•
Inspect the breaker for operation.
•
Connect:
12 V Battery [A]
0.6 Ω Resistance [B]
Radiator Fan Breaker [C]
Switch [D]
If the circuit in the breaker will not open within 60 seconds,
replace the breaker.
Radiator Fan Breaker Installation
•
Install:
Radiator Fan Breaker [A]
Holder [B]
•
Connect:
White Lead [C]
Blue/White Lead [D]
[E] Electrical Parts Case
[F] Right Side
Kommentare zu diesen Handbüchern